A new DUAL opto-nuclear probe has also been designed for the per-operative sentinel lymph node localization through dual radiation and fluorescence detections. The combined use of these two detection methods allows to nearly reach 100% sensitivity up from less than 80% by each method taken separately.

Description

A new DUAL opto-nuclear probe has also been designed for the per-operative sentinel lymph node localization through dual radiation and fluorescence detections. The combined use of these two detection methods allows to nearly reach 100% sensitivity up from less than 80% by each method taken separately.

Learn about the diseases that this device uses

BREAST CANCER

Sentinel node biopsy

In-clinic lesions detection

(<<ROLL>>, <<SNOLL>>)

 

GYNAECOLOGY

Laparoscopic detection of

Sentinel node in cancer of the

Cervix and endometrium

Sentinel node detection of vulva

Cancer

 

DERMATOLOGY

Melanoma

 

HEAD & NECK

Oral Cavity

Oropharynx (validation on process)

ENDOCRINOLOGY

Thyroid

Parathyroid

 

NUCLEAR MEDICINE

Percutaneous detection

Localization of gamma labelled areas

UROLOGY

Penile cancer

With a single readout module and numerous gamma probe options, the Europrobe 3.2 is a unique system that fulfills all needs of per and post-operative detection as well as per-cutaneous localisation within 7 major clinical fields: Breast, gynaecology, ENT, dermatology, endocrinology, urology and nuclear medicine.
The characteristics of the detector, its shape, size and sensitivity maybe adapted to any appropriate isotopes needed to meet clinical requirements. Every probe can be suited with an optional collimator.
All our probes are manufactured in biocompatible medical stainless steel, and a sterile biocompatible cover has been specially developed to suit the whole range.
Furthermore, the Europrobe probes are compliant with the IP68, ISO10993-5, ISO10993-10, ISO10993-11 biocompatibility standards.

CdTe probes
Eurorad has developed a wide range of probes based on CdTe detectors, developed and manufactured internally.
Several standard models are available, but customized probes can also be produced on request.

The multiple benefits of CdTe:
Work at room temperature.
Operate at low voltage (maximum 150V).
Highly accurate and offer excellent energy resolution at 140 keV (99mTc).
Very good detection efficiency between 20 and 170 keV.
Availability of small probes adapted for small incisions.
Available in wireless Bluetooth version.
Possibility of offering customized probes.

Csi probes
A pioneer in this field, Eurorad offers a very wide range of probes incorporating a CsI (Tl) scintillator coupled to an Si photodiode.

The multiple benefits of Csi:

Work at room temperature.
Offer a very good efficiency from 100 keV to 1 MeV.
Work with a low bias voltage unlike the PMT solution (typically 20V).
Available in wireless Bluetooth version.
Possibility of offering customized probes.